Largely manufactured from recycled glass (e.g. windscreens) and mineral base materials such as sand and without the use of binding agents. The ingredients are melted into molten glass, which is cooled and crushed into a fine powder. The powdered glass is poured into molds and heated (below the melting point) in a "sintering" process that causes the particles to adhere to one another. Next, a small amount of finely ground carbon-black is added and the material is heated in a "cellulation" process. Here, the carbon reacts with oxygen, creating carbon dioxide, which creates the insulating bubbles in the (material). CO2 accounts for more than 99% of the gas in the cellular spaces.
Cellulose insulation is a material made from recycled newspaper. The paper is shredded and inorganic salts, such as boric acid, are added for resistance to fire, mould, insects and vermin. The insulation is installed either blown or damp-sprayed depending on application.
Wood fibre
The success of wood fibre insulation derives from an attractive environmental profile combined with a whole bag of functions including rigid insulation, sheathing and sarking for timber frames, roofs and flooring as well as flexible insulation for studs and rafters.
Wood of course is renewable, it sequesters carbon during its growth and product production is relatively free from pollution. The insulation value of wood fibre boards is not as dimensionally efficient as some of the orthodox petro-chemical materials - but it's no slouch either - typically coming in with a 'k value' range of between 0.038-0.043 W/mK depending on format.
Hemp
Hemp fibres are produced from hemp straw of the hemp plant. Most hemp is imported, but an increasing amount of home-grown crop is becoming available. Hemp grows up to a height of nearly 4 metres within a period of 100-120 days. Because the plants shade the soil, no chemical protection or toxic additives are required for hemp cultivation. The product is composed of, usually, 85% hemp fibre with the ballance made up of polyester binding and 3-5% soda added for fire proofing.
Straw
Straw is an agricultural by-product, the dry stalks of cereal plants, after the grain and chaff have been removed. Straw makes up about half of the yield of cereal crops such asbarley, oats, rice, rye and wheat.
Cordek® has provided technical solutions for a wide range of construction requirements since formation in 1973. The Cordek® range of ground heave solutions is designed to protect suspended floor slabs, piled ground beams and pile caps from the effects associated with ground heave. In addition to ground heave protection, the product range includes systems which incorporate permanent formwork, insulation and passive ground gas venting options. Both standard and bespoke solutions are available to meet the specific ground heave protection requirements of the foundation design.
Cordek® company HX S and HX B products has been specially designed to protect reinforced suspended floor slabs, piled ground beams and pile caps from upward forces. Each grade of product offers different safe and fail loads to allow a specific level of pressure before the boards collapse and create a void around the affected area. On the other hand, HX Plus provides combined ground heave protection and integral insulation in a single product.
A compressible, low density Heaveguard EPS offered by Cordek® protects foundations against lateral heave.
Cordek® Filcor Structural Fill Solution
Soon Cordek® company came up with great non-degradable, structural fill solution called Filcor. This void former replaces traditional heavyweight construction materials. Made from polystyrene, Filcor 20 is commonly used as a lightweight material for forming voids and openings within concrete structures. Because of that, it became the most common product in everyday "groundworks" life. Though its low weight and price is most widely recognized as being the best price-value Cordek® product. Moreover, Filcor 20 price is the lowest compared to the other manufacturers. Wide range of higher Filcor grades can withstand thicker concrete slabs.
100mm Cellcore HG Grade 30/40 Ground Heave Protection EPS is a lightweight expanded polystyrene insulation board used in ground heave applications where the specification of the project mean that the standard Cellcore HX S Under Floor Slabs and Cellcore HX B Under Ground Beams products are not suita..
130mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
130mm Cellcore HX Plus thermal resistance is 1.39m2c/w
135mm Cellcore Cellvent HX Grade 7/10 combines the benefits of the Cellcore HX range with Ventform to alleviate the effects of ground heave whilst also providing an excellent gas venting medium.
Cellvent HX is available in a range of specifications and can be used in conjunction with gas membrane..
135mm Cordek Cellcore Cellvent HX Cellular EPS Void Former
Cellvent HX Grade 7/10 Maximum Concrete Depth 220mm
Reinforced ground floor slabs where subsidence is not expected
Used to alleviate the effects of ground heave and gas venting
Combined ground heave protection and passive gas venting system
HX B Under Beam 2400x600x155mm Grade 7-10, an unique EPS based board with hollow core and moulded legs used beneath reinforced concrete ground beams and pile caps.
Cellcore HX B Grade 7-10 is fully tested, calculated and calibrated for concrete thickness up to 220mm to protect ground beams agains..
155mm thick Cellcore Under Beam HX B Board cut to 600mm widths
HX B Ground Beams Grade 7-10 max. concrete depth up to 220mm
Protects ground beams against the potential effects of ground heave
Used beneath reinforced concrete ground beams and pile caps
Special hollow construction expanded polystyrene (EPS) block
155mm Cordek Cellcore HX B Under Beam 7/10 is a concrete ground beam protection EPS block designed for use beneath reinforced concrete ground beams and pile caps to protect against the potential effects of ground heave.
Cellcore HX B Grade 7/10 is calculated and calibrated for concrete thickness..
155mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
155mm Cellcore HX Plus thermal resistance is 2.08m2c/w
155x450x450mm Claymaster Pile Collars are compressible low density Expanded Polystyrene (EPS) products, used when foundations need to be protected against ground heave.
The Heaveguard (Claymaster) pile collar is an engineered material in green or pink color designed to safeguard piles against upl..
160mm Cordek Cellcore HX S Under Slab (Grade 7/10) is a lightweight expanded polystyrene anti heave protection board designed for use beneath reinforced concrete floor slabs.
Cellcore HXS Grade 7/10 is calculated and calibrated for concrete thickness up to 220mm (has been tested to achieve the sp..
180mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
180mm Cellcore HX Plus thermal resistance is 2.78m2c/w
200mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
200mm Cellcore HX Plus thermal resistance is 1.39m2c/w
205mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
205mm Cellcore HX Plus thermal resistance is 3.47m2c/w
Cordek Cellcore 220mm HX B Under Beam 7/10 is a lightweight block designed for use beneath reinforced concrete ground beams and pile caps to protect against the potential effects of ground heave.
HX B (Concrete Ground Beams Protection) Grade 7/10 is calculated and calibrated for concrete thickne..
Cellcore HX B Under Beam 7-10 is a 220mm thick, 600mm wide and 2400mm long EPS block with hollow core used beneath reinforced concrete ground beams and pile caps.
Cordek HX B for Ground Beams Grade 7-10 is calculated and calibrated for concrete thickness up to 220mm to protect ground beams agains..
220mm thick Cellcore Under Beam HX B Board cut to 600mm widths
HX B Ground Beams Grade 7-10 max. concrete depth up to 220mm
Protects ground beams against the potential effects of ground heave
Used beneath reinforced concrete ground beams and pile caps
Special hollow construction expanded polystyrene (EPS) block
225mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
225mm Cellcore HX Plus thermal resistance is 2.08m2c/w
225mm Cordek Cellcore HX S Under Slab 7/10 is a lightweight expanded polystyrene (EPS) block designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave by reducing the upward force transmitted to the structure from ground heave.
Cordek Cellco..
230mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
230mm Cellcore HX Plus thermal resistance is 4.17m2c/w
250mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
250mm Cellcore HX Plus thermal resistance is 2.78m2c/w
265mm Cellcore HX Plus EPS Grade 7/10 Insulated Heave Protection Board is a two in one product designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene ..
265mm Cellcore HX Plus thermal resistance is 1.39m2c/w
275mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
275mm Cellcore HX Plus thermal resistance is 3.47m2c/w
290mm Cellcore HX Plus EPS Grade 7/10 Insulated Heave Protection Board is a two in one product designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene ..
290mm Cellcore HX Plus thermal resistance is 2.08m2c/w
300mm Cellcore HX Plus Grade 7/10 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
300mm Cellcore HX Plus thermal resistance is 4.17m2c/w
315mm Cellcore HX Plus EPS Grade 7/10 Insulated Heave Protection Board is a two in one product designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene ..
315mm Cellcore HX Plus thermal resistance is 2.78m2c/w
340mm Cellcore HX Plus EPS Grade 7/10 Insulated Heave Protection Board is a two in one product designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene ..
340mm Cellcore HX Plus thermal resistance is 3.47m2c/w
365mm Cellcore HX Plus EPS Grade 7/10 Insulated Heave Protection Board is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene..
365mm Cellcore HX Plus thermal resistance is 4.17m2c/w
For use beneath reinforced concrete floor slab insulation
365mm Cellcore HX PLUS Insulated Heave Protection
Cellcore HX Plus range is BBA certified (no.11/4862)
2 in 1 Solution - Insulation and Heave Protection Board
450mm x 450mm x 85mm Pile Collars (Claymaster) are compressible low density Expanded Polystyrene products, used when foundations need to be protected against ground heave.
The Heaveguard (Claymaster) pile collar is an engineered material in green or pink color designed to safeguard piles against ..
450x450x220mm Pile Collars Claymaster (Heaveguard) are compressible low density Expanded Polystyrene (EPS) products, used when foundations need to be protected against ground heave.
The Heaveguard (Claymaster) pile collar is an engineered material in green or pink color designed to safeguard pile..
50mm Cordek Heaveguard Foundation Protection Against Ground Heave is a lightweight, compressible-fill EPS designed to protect foundations against effects of ground heave.
Claymaster (Heaveguard) is a compressible material used typically on the inside face of piled ground beams or deep trench fill..
NHBC Clay Heave Protection EPS Board
Ground Heave Protection Solution for Clay
Soil heave potential: Medium
BBA Agrement Certificate No. 17/5448
Low density compressible expanded polystyrene (EPS)
85mm Cordek Cellcore HX B Under Beam 7/10 is a lightweight enhanced EPS (expanded polystyrene) board designed for use beneath reinforced concrete ground beams and pile caps to protect against the potential effects of ground heave.
Grade 7/10 is calculated and calibrated for concrete thickness up..
85mm x 600mm x 2400mm Cordek Cellcore HX B Under Beam Grade 7-10 is a special hollow construction polystyrene block used beneath reinforced concrete ground beams and pile caps.
Cellcore HX B Grade 7-10 is fully tested, calculated and calibrated for concrete thickness up to 220mm to protect ground..
85mm thick Cellcore Under Beam HX B Board cut to 600mm widths
HX B Ground Beams Grade 7-10 for concrete thickness up to 220mm
Protects ground beams against the potential effects of ground heave
Used beneath reinforced concrete ground beams and pile caps
Special hollow construction expanded polystyrene (EPS) block
90mm Cordek Cellcore HX S Under Slab 7/10 is used beneath reinforced concrete floor slabs to protect against the potential effects of ground heave by reducing the upward force transmitted to the structure from ground heave.
Anti Heave Board Cordek Cellcore hxs in Grade 7/10 is calculated and cali..
Cordek Filcor Void Former EPS is a lightweight but durable structural fill board used as a void former solution for forming openings and voids within a wide range of concrete structures.
The Filcor panels are a great alternative to more traditional fill materials, available in 2400mm long x 1200m..
Swimming Pools, Podium Slabs
Hard and Soft Landscaping, Steps, Ramps and Shapes
Wide range of Compressive Strengths available
Flame Retardant (FR) properties - Water resistant
Minimum depth of 25mm and a Maximum depth of 1200mm.
Cordek Tri-Gas Membrane Ground Gas Protection 100m2 roll is a reinforced gas membrane used where resistance to methane, carbon dioxide or radon gas is required in construction applications, predominantly within the foundation design.
This high performance multilayer 0.4mm thick, 2000mm wide and 5..
Cordek Filcor Joint & Stick is a high performance, highly durable, flexible, waterproof, single component MS Polymer joint sealant and adhesive.
Joint & Stick is used to bond Filcor to most common materials used in construction and for fixing, jointing, and sealing formwork systems.
The produc..
Flexible Cordek Filcor joint sealant and adhesive
Fully waterproof Filcor joint sealant and adhesive
Resists temperature from -40°C to 100°C
Applied using a standard cartridge gun
Compatible with Cordek Filcor and formwork systems
100mm Cellcore HG Grade 40/50 is a lightweight expanded polystyrene (EPS) insulation board designed for use in ground heave protection applications where the specification of the project mean that the standard Cellcore HX S Under Floor Slabs and Cellcore HX B Under Ground Beams products are not suit..
130mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
130mm Cellcore HX Plus thermal resistance is 1.39m2c/w
135mm Cellvent HX Grade 9/13 is a lightweight cellular void former made of Cellcore HX range with Ventform to alleviate the effects of ground heave whilst also providing an excellent gas venting.
Cellvent HX is available in a range of specifications and can be used in conjunction with gas membran..
135mm Cordek Cellcore Cellvent HX Cellular EPS Void Former
Cellvent HX Grade 9/13 Maximum Concrete Depth 300mm
Reinforced ground floor slabs where subsidence is not expected
Used to alleviate the effects of ground heave and gas venting
Combined ground heave protection and passive gas venting system
155mm Cordek Cellcore HX B Under Beam Block (Concrete Ground Beams Protection) 9/13 is used beneath reinforced concrete ground beams and pile caps to protect against the potential effects of ground heave.
HX B Grade 9/13 is calculated and calibrated for concrete thickness up to 300mm (has been t..
155mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
155mm Cellcore HX Plus thermal resistance is 2.08m2c/w
155mm x 450mm x 600mm Pile Collar Heaveguard is a compressible low density Expanded Polystyrene product, used when foundations need to be protected against ground heave.
The Heaveguard (Claymaster) pile collar is an engineered material in green or pink color designed to safeguard piles against up..
160mm Anti Heave Board Cordek Cellcore HX S Under Slab 9/13 is an expanded polystyrene (EPS) block designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave.
Cellcore HXS Grade 9/13 is calculated and calibrated for concrete thickness up to 3..
180mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
180mm Cellcore HX Plus thermal resistance is 2.78m2c/w
200mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
200mm Cellcore HX Plus thermal resistance is 1.39m2c/w
205mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
205mm Cellcore HX Plus thermal resistance is 3.47m2c/w
220mm Cordek Cellcore HX B Under Beam 9/13 is an expanded polystyrene block designed for use beneath reinforced concrete ground beams and pile caps to protect against the potential effects of ground heave.
HX B (Concrete Ground Beams Protection Block) Grade 9/13 is calculated and calibrated for ..
220x600x2400mm HX B Under Beam 9-13, used beneath reinforced concrete ground beams and pile caps, a special hollow core construction EPS block with moulded legs.
Cordek Cellcore HX B Grade 9-13 is calculated and calibrated for concrete thickness up to 300mm to protect ground beams against the eff..
220mm thick Cellcore Under Beam HX B Board cut to 600mm widths
HX B Ground Beams Grade 9-13 max. concrete depth up to 300mm
Protects ground beams against the potential effects of ground heave
Used beneath reinforced concrete ground beams and pile caps
Special hollow construction expanded polystyrene (EPS) block
225mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
225mm Cellcore HX Plus thermal resistance is 2.08m2c/w
225mm Cordek Cellcore HX S Under Slab Anti Heave Board (9/13) is used beneath reinforced concrete floor slabs to protect against the potential effects of ground heave.
The HX S Grade 9/13 is calculated and calibrated for concrete thickness up to 300mm (has been tested to achieve the specified pe..
230mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
230mm Cellcore HX Plus thermal resistance is 4.17m2c/w
250mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
250mm Cellcore HX Plus thermal resistance is 2.78m2c/w
265mm Cellcore HX Plus EPS Grade 9/13 Insulated Heave Protection Board is a two in one product designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene ..
265mm Cellcore HX Plus thermal resistance is 1.39m2c/w
275mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
275mm Cellcore HX Plus thermal resistance is 3.47m2c/w
290mm Cellcore HX Plus EPS Grade 9/13 Insulated Heave Protection Board is a two in one product designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene ..
290mm Cellcore HX Plus thermal resistance is 2.08m2c/w
300mm Cellcore HX Plus Grade 9/13 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene she..
300mm Cellcore HX Plus thermal resistance is 4.17m2c/w
315mm Cellcore HX Plus EPS Grade 9/13 Insulated Heave Protection Board is a two in one product designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene ..
315mm Cellcore HX Plus thermal resistance is 2.78m2c/w
340mm Cellcore HX Plus EPS Grade 9/13 Insulated Heave Protection Board is a two in one product designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene ..
340mm Cellcore HX Plus thermal resistance is 3.47m2c/w
365mm Cellcore HX Plus EPS Grade 9/13 Insulated Heave Protection Board is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene..
365mm Cellcore HX Plus thermal resistance is 4.17m2c/w
For use beneath reinforced concrete floor slab insulation
365mm Cellcore HX PLUS Insulated Heave Protection
Cellcore HX Plus range is BBA certified (no.11/4862)
2 in 1 Solution - Insulation and Heave Protection Board
75mm Heaveguard Ground Heave Claymaster is an expanded polystyrene board used to protect foundations against effects of ground heave on the inside face of piled ground beams or deep trench fill foundations.
Heaveguard (claymaster) works by surrounding the pile cap with a layer of low density, com..
Clay Heave Protection
Board coverage: 2.88m2
Soil heave potential: Medium
BBA Agrement Certificate No. 17/5448
Low density compressible expanded polystyrene (EPS)
85mm Cordek Cellcore HX B Under Beam Grade 9-13 is a 2400mm long by 600mm wide hollow core EPS block used beneath reinforced concrete ground beams and pile caps.
Cellcore HX B Grade 9-13 is fully tested, calculated and calibrated for concrete thickness up to 300mm to protect ground beams against ..
85mm thick Cellcore Under Beam HX B Board cut to 600mm widths
HX B Ground Beams Grade 9-13 for concrete thickness up to 300mm
Protects ground beams against the potential effects of ground heave
Used beneath reinforced concrete ground beams and pile caps
Special hollow construction expanded polystyrene (EPS) block
85mm Cordek Cellcore HX B Under Beam Board 9/13 is used beneath reinforced concrete ground beams and pile caps to protect against the potential effects of ground heave.
Grade 9/13 is calculated and calibrated for concrete thickness up to 300mm (has been tested to achieve the specified performanc..
85mm x 450mm x 600mm Pile Collar Heaveguard is a compressible low density Expanded Polystyrene product, used when foundations need to be protected against ground heave.
The Heaveguard (Claymaster) pile collar is an engineered material in green or pink color designed to safeguard piles against upl..
90mm Anti Heave Board Cordek Cellcore HX S Under Slab 9/13 is an expanded polystyrene (EPS) block used beneath reinforced concrete floor slabs to protect foundations against the potential effects of ground heave.
HXS Grade 9/13 is calculated and calibrated for concrete thickness up to 300mm (has ..
155mm x 600mm x 2400mm Cordek Cellcore HX B Under Beam Grade 9-13 is a hollow core construction EPS block used beneath reinforced concrete ground beams and pile caps.
Cellcore HX B Grade 9-13 is fully tested, calculated and calibrated for concrete thickness up to 300mm to protect ground beams aga..
155mm thick Cellcore Under Beam HX B Board cut to 600mm widths
HX B Ground Beams Grade 9-13 max. concrete depth up to 300mm
Protects ground beams against the potential effects of ground heave
Used beneath reinforced concrete ground beams and pile caps
Special hollow construction expanded polystyrene (EPS) block
Cordek Filcor 20 is a lightweight structural fill material used as a void former solution for forming openings and voids within concrete structures in landscaping, slabs, swimming pools, steps, ramps and shapes.
Filcor in Grade 20 is calculated and calibrated for concrete thickness up to 800mm (h..
Swimming Pools, Podium Slabs
Hard and Soft Landscaping, Steps, Ramps and Shapes
Pile Collar Heaveguard 220mm x 450mm x 600mm is a compressible low density Expanded Polystyrene product, used when foundations need to be protected against ground heave.
The Heaveguard (Claymaster) pile collar is an engineered material in green or pink color designed to safeguard piles against up..
100mm Cellcore HG Grade 50/65 is a lightweight expanded polystyrene (EPS) insulation board designed for use in ground heave protection applications where the specification of the project mean that the standard Cellcore HX S Under Floor Slabs and Cellcore HX B Under Ground Beams products are not suit..
100mm Cordek Heaveguard Protection Against Ground Heave is a lightweight, compressible-fill EPS material designed to protect foundations against effects of ground heave.
Heaveguard (Claymaster) is typically used on the inside face of piled ground beams or deep trench fill foundations.
Cordek H..
Clay Heave Protection
Board coverage: 2.88m2
Soil heave potential: Medium
BBA Agrement Certificate No. 17/5448
Low density compressible expanded polystyrene (EPS)
130mm Cellcore HX Plus Grade 13/18 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene sh..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
130mm Cellcore HX Plus thermal resistance is 1.39m2c/w
135mm Cellvent HX Grade 13/18 is designed for use under suitably reinforced ground floor slabs where subsidence is not expected, combining the benefits of the Cellcore HX range with Ventform.
Cellvent HX is available in a range of specifications and can be used in conjunction with gas membranes, ..
135mm Cordek Cellcore Cellvent HX Cellular EPS Void Former
Cellvent HX Grade 13/18 Maximum Concrete Depth 460mm
Reinforced ground floor slabs where subsidence is not expected
Used to alleviate the effects of ground heave and gas venting
Combined ground heave protection and passive gas venting system
155mm Cordek Cellcore HX B Under Beam 13/18 is an expanded polystyrene (EPS) block designed for use beneath reinforced concrete ground beams and pile caps to protect against the potential effects of ground heave.
HX B Grade 13/18 is calculated and calibrated for concrete thickness up to 460mm (h..
155mm Cellcore HX Plus Grade 13/18 (EPS) Insulated Heave Protection is a two in one solution designed for use beneath reinforced concrete floor slabs to protect against the potential effects of ground heave with the additional Filcor EPS100 insulation layer protected by a ultra thin polypropylene sh..
Under Concrete Floor Slab Insulation Board
HX Plus range is BBA certified (no.11/4862)
Cellcore HX Plus Insulated Heave Protection Board
Beneath reinforced concrete floor slab insulation
155mm Cellcore HX Plus thermal resistance is 2.08m2c/w
HX B Under Beam Cordek Cellcore 155x600x2400mm Grade 13-18, a reinforced concrete ground beams and pile caps board, an EPS block with hollow core and moulded legs.
Cellcore HX B Grade 13-18 is fully tested, calculated and calibrated for concrete thickness up to 460mm to protect ground beams again..
155mm thick Cellcore Under Beam HX B Board cut to 600mm widths