- 50mm Unilin SR/PR Safe-R Phenolic Foam Pitched Roof Insulation Board
- Rigid foam insulation board with a composite foil-facing on both sides
- Used above or between the roof rafters reducing thermal stress and condensation risk
- SR/PR Roofs (ventilated, hybrid, sloped or warm) provides the most efficient U-Values
- Certified lambda (thermal conductivity) of 0.020 W/mK and Euroclass C s1 d0 fire classification
In Stock
- Brand: Unilin Insulation (UK) known as Xtratherm
- Model: 50mm Unilin SR/PR Roof
- Weight: 30.00kg
- Dimensions: 2,400mm x 1,200mm x 50mm
- SKU: 50mm Unilin SR/PR Roof
- Product code: P1-3474
- MPN: 50mm Unilin SR/PR Roof
Options available
50mm Safe-R Phenolic Unilin SR/PR is a warm roof rigid phenolic foam insulation board with a composite foil facing on both sides, for use in pitched roofs in new build and refurbishment projects.
Safe-R Pitched Roof Unilin SR/PR on sloped roofs (ventilated, hybrid or warm roofs) provides the most efficient U-Values with minimal intrusion into valuable living space.
SR/PR Safe-R is manufactured to EN 13166 by Unilin Insulation with certified lambda (thermal conductivity) of 0.020 W/mK and Euroclass C s1 d0 fire classification.
The thermal bridge which occurs through the joists can be addressed by placing a layer of SR/PR to the underside, before the plasterboard is fixed.
The roof construction is a critical element in the building fabric and is an area at high risk of heat loss.
Using SR/PR will reduce heat loss while also delivering excellent thermal bridging details.
Warm Roof construction is a particularly effective way of insulating complex roofs.
SR/PR is durable, rot proof and sufficiently stable to remain effective as insulation for the life of the building.
Specification:
Thickness: 50mm
Width: 1200mm
Length: 2400mm
Size: 50mm x 1200mm x 2400mm
Pack Quantity: 6 sheets
Pack Coverage: 17.28m2
Board Coverage: 2.88m2
Profile: Square Edge
R-Value: 2.35 m2K/W
Density (Foam Core): 32kg/m3
Thermal Conductivity: 0.020 W/mK
Compressive Strength: >120 (kPa)
Reaction to Fire: Euroclass C, s1-d0
Unilin SR/PR Safe-R Pitched Roof Board Features:
· Reduced thermal bridging.
· Provides the most efficient U-Values.
· Lightweight and easy to install.
· Reduced risk of condensation.
· Avoids intrusion into the living area.
· Premium phenolic rigid foam insulation.
· Suitable for new build and refurbishment projects.
· Suitable for domestic and non-domestic buildings.
· Certified lambda (thermal conductivity) of 0.020 W/mK.
· Declared Euroclass C s1 d0 fire classification.
· Manufactured to EN 13166 by Unilin Insulation.
· BBA Certified (certification no. 10/4803).
· Durable, rot proof and stable.
Unilin SR/PR Phenolic Pitched Roof Insulation Board Installation Guidelines:
· Ventilated Roof - Fix positioning battens to inner face of rafters, flush with the top edge of the timber.
· Allow space for ventilation gaps, normally 50mm (May be reduced depending on breather membrane certification).
· Cut boards with fine toothed saw to fit tightly between rafters, flush with the bottom of the rafter.
· Allow slight oversize of cut to achieve ‘friction fit’ and seal any gaps with expanding foam.
· If an additional second layer is required, this should be fixed to the underside of the rafter.
· Run the second layer transverse to the first with joints tightly butted.
· Fix with nails to hold insulation in place until plasterboard is installed.
· Provide a separate vapour control layer between insulation and plasterboard or alternatively, tape the joints of the insulation with an aluminium foil tape.
· Finish with plasterboard fixed with dry lining screws.
· Screw fix every 150mm, 12mm from edge of boards ensuring a minimum 25mm penetration into the rafter or alternatively follow plasterboard manufacturer installations guidance.
· Alternatively the second layer can be achieved with SR/TB-MF Drylining board.
· Repeat steps 1 to 3 and replace the second layer with SR/TB-MF, a ready made Phenolic insulation board bonded to plasterboard.
· Where joints between sheets of SR/TB-MF are unsupported by the rafters, timber noggins should be installed.
· Seal and tape the joints of the plasterboard in accordance with Standard Drylining Practice.
· Hybrid Roof - Follow the same procedure as a ventilated roof except an approved Vapour Permeable underlay is used above the rafter allowing the 50mm ventilation space to be dispensed with.
· Typically, a 25mm unventilated void should be maintained; Agrément certification covering the membrane should be consulted.
· Warm Roof - Ensure cavity wall insulation has continued to roof height to meet with the roof insulation.
· Fix a treated timber stop rail to the end of the rafter at the eaves.
· Lay SR/PR staggered jointed over the rafters.
· Ensure joints are tightly butted and fill any gaps with expanding foam.
· Joints should be fully supported by rafters.
· Boards can be temporarily fixed with nails.
· Fix 38mm x 50mm counter battens with approved fixings through the SR/PR into the rafter.
· The amount of fixings is determined by the fixing manufacturer who can also provide wind load calculations.
· A breathable sarking membrane should be fitted; refer to manufacturer’s Agrément certification.
· Ventilation may have to be provided subject to that certification and minimises the risk of interstitial condensation forming on the underside of the membrane.
· Providing an unventilated void under the membrane can improve thermal performance.
· Secure 50mm x 25mm tiling battens through counterbatten and SR/PR to the rafter.
· If an additional second layer is required, this should be fixed between the rafters.
· Cut boards with fine toothed saw to fit tightly between rafters, flush with the top of the rafter.
· Allow slight oversize of cut to achieve ‘friction fit’ and seal any gaps with expanding foam.
· Provide a separate vapour control layer between the bottom of the rafter and plasterboard.
· Finish with plasterboard fixed with dry lining screws.
· Screw fix every 150mm, 12mm from edge of boards ensuring a minimum 25mm penetration into the rafter or alternatively follow plasterboard manufacturer installations guidance.
· ACDs must be followed to ensure that installation is in accordance with current Building Regulations and accounted for in the energy calculation.
*Further information may be found in our Downloads section.
Fairly easy access to all PDF files.
Datasheet ǀ Declaration of Performance - DoP ǀ BBA Certificate ǀ Installation Guide ǀ Certificates ǀ Brochure ǀ SPEC Sheet
*Special Product - Non returnable cancelable.
specification | |
Board covarage | 17.28 m2 |
Colour | Light pink |
Density | 32 Kg/m3 |
Length | 2400mm |
Material | Phenolic Rigid Foam |
Pack Coverage | 17.28m2 |
Pack Quantity | 6 boards |
Profile | Square Edge |
R-Value | 2.35 m2K/W |
Size | 50mm x 1200mm x 2400mm |
Thermal Conductivity | 0.020 W/mK |
Thickness | 50mm |
Width | 1200mm |
Fire Reaction | Euroclass C, s1-d0 |
Coverage | 2.88m2 |
Finish | Composite foil-facing on both sides |
Quantity | 6 sheets |
Shipping method | Articulated Vehicle ǀ Courier |
Applications | Pitched, ventilated, hybrid or warm roofs |
BBA Certified | Yes, no. 10/4803 |
Fixing method | Above or between roof rafters |
Foil faced | Yes, foil facings on both sides |
ETA Notification | Yes |
U-value | 0.11 - 0.17 W/m²K |
Features | Provides the most efficient U-Values |
Manufacturer | Unilin Insulation® |
We deliver insulation materials to Mainland UK only. Deliveries to Highlands, Northern Ireland, Isle of Wight etc.. might be possible at additional cost.
We offer free delivery on most of the orders above £300 (excluding VAT) (except special products - shipping cost via courier - products marked ''Request A Quote'')
Delivery of some insulation materials might be extended due to the current situation (Covid-19, stock shortages, allocations).
If you need materials quickly please contact us - we will do our best to help you source materials needed.
We do not deliver on weekends and bank holidays. Sometimes we can deliver on Saturdays - please check with us before placing the order.
If you need any further information please contact us tel. 02081910776
We can help to calculate price per m2 or linear meter (one meter in length) cost, please just contact us via phone 02081910776, email or live chat. Alternatively, you can work it out yourself quickly and easily: to get cost per meter square please divide price shown in orange area by ''Required area (m2)'' Example price of £28.80 divided by board coverage 2.88m2 = cost of £10.00 per m2.
INSTALLERS
No matter whether you choose a local installer or a national company, there’s a few tips to help you find the right installer for your home insulation improvements, such as asking for recommendations and making sure that they’re part of a certification scheme. This makes sure that they have the right skills and standards of workmanship to carry out the installation, and you can be sure that they know exactly what they are doing.
4 TIPS FOR CHOOSING THE BEST INSULATION INSTALLER
1. Thermal inspection picture in portfolio
It’s worth seeing a installer’s previous work. There’s no harm asking if you can see any properties nearby that they’ve installed insulation in. Best way would be to see Infrared Thermal Imaging Inspections. Thermal cameras spot small, but key changes in temperature in different areas of a house, identifying problematic areas that the human eye never could and some that a visual inspection could only hypothesize.
2. Reviews
Along with checking recommendations and previous work, finding reviews online can often be a great way to find out if they provide a good service or not. However, it’s best not to solely rely on reviews you may find or review websites, as there’s no controlling who writes them.
3. Compare prices
Comparing prices will also ensure companies can’t take advantage of you and give you a fair price.
4. Word of Mouth
The best way to find a great insulation installer is through recommendations. Make sure you ask friends and family. They will most likely give you their honest opinion and can tell you from first hand experience.
Whether you require a wall, cladding, external wall, loft or floor insulation fitted, you can find and hire your local insulation installers from popular UK web pages. A simple internet search will return thousands of potential installers near your area.
https://www.nia-uk.org/find-an-installer/
https://www.ratedpeople.com/local-thermal-insulation
STOCKIST
We are the stockist of construction materials and related products for both trade and DIY from most recognizable brands in the UK like Cordek, RCM, Promat, Rockwool, Isover, Celotex, Xtratherm, Ursa, Low-E, Cedral, Kingspan, Dufaylite, British Gypsum, K-rend, Ecotherm, Iko enertherm, Kay-Metzeler, Terrawool to allow you to complete your insulation job on time at competitive prices and the highest standards.